42
Figure 35 – DHW Set-Point Screens
Press the button when the display panel is powered ON to change the DHW Set-Point. The DHW icon
and current set-point will display and ash. This indicates that the DHW Set-Point can be changed. Factory
DHW Set-Point is 120°F(49°C). Initial DHW Set-Point range is 100 – 140°F (38 – 60°C).
The recommended starting temperature is 120 °F (49°C).
Turn the dial counterclockwise to lower and clockwise to raise the DHW set-point. After changing the
temperature, press the button to save the set-point.
To change the DHW Set-Point above 121°F (49.5°C), press and hold the button when the display panel
is powered ON.
The current DHW set-point will display. The DHW icon will ash. Then press and hold the button for ve
seconds. The scald warning icon (High Temperature Warning icon) will display. High temperature DHW Set-
Point range is 125°F – 140°F (52°C – 60°C).
Turn the dial counterclockwise to lower and clockwise to raise the DHW set-point. After changing the
temperature, press the button to save the set-point.
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a setting of 140°F (60°C). Water
temperature over 125°F can instantly cause severe burns, or death, from scalds. Children, disabled, and elderly are at the highest
risk of being scalded. See instruction manual before setting temperature at appliance. Feel water before bathing or showering!
DANGER
APPROXIMATE TIME / TEMPERATURE RELATIONSHIPS IN
SCALDS
120°F
More than 5 minutes
125°F
1 ½ to 2 minutes
130°F
About 30 seconds
135°F
About 10 seconds
140°F
Less than 5 seconds
145°F
Less than 3 seconds
150°F
About 1 ½ seconds
155°F
About 1 second
E.STATUSDISPLAYMODE
Status Display Mode will activate when power button is pressed and held for ve seconds
when the display panel is turned on at Standby Mode.
Figure 36 – Status Mode Screens
Chapter3HowtoUseTheControlPanel

Other manuals for Rheem RTGH-RH11DV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem RTGH-RH11DV and is the answer not in the manual?

Rheem RTGH-RH11DV Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas
Maximum Flow Rate11 GPM
Energy Factor0.82
Warranty12 years
Inlet Water Temperature Range40-90°F
Voltage120 V
Ignition TypeElectronic
VentingDirect Vent
Gas Connection3/4 inch
Water Connection3/4 inch
Temperature Adjustment Range98°F to 140°F

Related product manuals