Index Default Parameter Description
1:EH N/A Error History
Allows the Installer to View the Unit Error History
Range: E0:XX E9:XX
2:CE
Clear Error & System
initialize
EHIS :Error History
rH : Burn Hour
bnCY : Burn Cycle
PPHr : Pump Running Time
In: System initialize
3:FC GA Unit
Use to choose unit (Water ow rate, Temperature)
LIt
: Liter/minute, Celsius
GAL °F : Gallon/minute, Fahrenheit
4:FH 00 Maximum Fan Speed
Adjusts Maximum Fan Speed
Range: -30 - +30
5:FL 00 Minimum Fan Speed
Adjusts Minimum Fan Speed
Range: -30 -+30
6:RC oFF
Recirculation Pump
Operation
Turns the Recirculation Pump On and Off
Range: On Pump On, oFF Pump Off
7:RM Itnl Recirculation Mode
NOTE:
6:RC must be set to On to select 7:RM
Sets the Recirculation Mode
Range: ItnL Internal Recirculation
EtnL External Recirculation / On Demand Kit,
tt24 Tilte 24 Mode, bYPS-Cross over
8:RT HI-2
Recirculation
Temperature
Sets Recirculation Temperature
Range: LO Low Temperature, HI-1 Middle Temperature,
HI-2 High Temperature
9:HT HI-2 Hot Water Temperature
Sets Hot Water Temperature
Range: LO Low Temperature, HI-1 Middle Temperature,
HI-2 High Temperature
10:IV 6 Prevent Ignition
Temporarily disables the water heater from igniting for a set period
of time.
Range: 0 20 Minutes
11:HA 0 - 2 High Elevation Mode
This water heater may be installed at elevations up to 10,000 feet
and operate on either Natural or LP. The appliance will de-rate by 4%
for each 1,000 feet above sea level.
Select the appropriate installation location as described below.
Selects Installation Location for Proper Water Heater Operation at
Altitude:
0-2 for installation locations from sea level to 2,000 feet
2-5 for locations from 2,000 to 5,000 feet
5-8 for locations from 5,000 to 8,000 feet
Default: 0 2
NOTE: Use a combustion analyzer to ensure CO and CO
2
are
within the ranges shown in this manual. Adjust the offset screw in
the clockwise (positive) or counterclockwise
(negative) directions (approximately 1/8 turn) if the measured CO
2
value on LOW FIRE
is out of range.
Index Default Parameter Description
12:Cn oFF Cascade
Enables Cascade Mode on the water heater.
Range: on – Cascade is used, oFF – Cascade is not used
13:Eh on Common Vent
NOTE:
12:Cn must be set to On to select 13:Eh
Enables Common Venting on the water heater.
Range: on – Common Venting is used,
oFF – Common Venting is not used
14:T1 oFF Test Mode 1
Used to test the water heater when operating in Internal Recirculation Mode only.
The water heater may operate while Test Mode 2 is operating.
Range: on, oFF
15:T2 oFF Test Mode 2
Used to purge air from the water heating system with an external recirculation
pump.
The water heater does not need to operate while Test Mode 2 is operating.
Range: on, oFF
Table 26 – Installer Mode Descriptions
Toggle through displayed items by turning the dial . To change an item, press the Dial button .
Displayed items can be changed by turning the dial counterclockwise to lower, and clockwise to raise, the
displayed value.
To save settings, press the Dial button again.
To leave Installer Mode, press button again. The water heater will return to power off mode.
H.USINGRECIRCULATIONMODES–STEP1
The following section explains and details the use of the Internal / External Recirculation Modes.
Preheat or Internal Recirculation Modes – When calls for hot water are satised, the water heater is factory
programmed to Preheat and automatically maintain the temperature set point of the water heater – 24 hours a
day, 7 days a week. The differential setting can be adjusted to control the temperature set point.
Internal Recirculation Mode allows the installer to program specific recirculation functions by day and
time to circulate and heat water more efciently - when the user most needs hot water. See Recirculation
Functions, this manual, for details.
External Recirculation Mode This mode keeps an external recirculation loop warm to make hot water
production more efcient and also aid in freeze protection. An external recirculation line must be installed
in order to recirculate water externally. The installer may program specic recirculation functions by day
and time to circulate and heat water when the user most needs hot water. See Recirculation Functions, this
manual, for details.
To set Recirculation Modes:
1. Installer Mode will activate when is pressed and held for ve seconds while the water heater display
is powered Off.
2. Turn the dial to 6:RC. Press the Dial button . “oFF” will ash when the 6:RC setting is ready to be
changed.
3. Turn the dial to “oFF” to turn off the Recirculation Pump, or “on” to turn the Recirculation Pump on.
Press the dial button to select the setting and return to the Installer Mode.
Figure 39 –6:RC - Recirculation Pump Operation
Chapter3HowtoUseTheControlPanel