56
Errorcode Meaning Condition
Ignitionfailure(Manualrestore)
Duringburningoperation,ifitfailed
toignite10timescontinuously,
errorcode11willappear.
Failureevent
Ifitfailedtodetect󰘱ameduringignitionsequencepre-purgetimewillexceed10secs,andpost-purgewill
beperformedaftertheignitioncausesmanualrestoreerror.
Checkpoint
Chapter4Troubleshooting
Check󰘱ame
detectorsensor’s
connectingline
and󰘰xedspot.
③Checkcolorchangesof󰘱ameobservationport.Afterseparating
stopringbyseeingcolorchanges,replacethe󰘱ameobservation
port.
■FrommorethanDC2.5Vafterignitionsafetycut-o󰘯willappear
WhensettingbeforeignitionislessthanDC2.5V:Replace󰘱amesensor.
WhensettingbeforeignitionismorethanDC2.5V:Replacethe󰘱ameobservationglassandgasket.
Checkwire
colorofconnector.
(CN7:red①,
black⑧)