Errorcode Meaning Condition
ExcessFanSpeeddetected
(Manualrestore)
Whenfanspeedexceedsnormal
valuesduringcombustion,error
code41willappear.
Failureevent
ThecircuitboardhasFanSpeeddata.Beforeignition,comparewithstandardFanSpeedbeforeignition
anderrorappearswhenexceedingstandardrange,stopalloftheoutputsexceptpost-purge.
Checkpoint
①CheckAPSandcircuitboardconnection.
②Verifythatthecondensatetrapanddrainpipearefreeof
obstructions.
③Checktheexhaustandintakepipesforblockage.
④Toresetthiserrorcode,thepowerneedstobedisconnected
andthenreconnected.