68
Errorcode Meaning Condition
Water Leakage
(Manualrestore)
WhentheWaterLeakageDetector
detectswater,errorcode45will
appear.
Failureevent
StopalloftheoutputsexceptfanwhentheWaterLeakageDetectorattachedonbaseunderplatedetected
thewater,itrestoresmanually.
Checkpoint
①Closethewaterinletvalve.
②ChecktheWaterLeakageDetector'swire.(CN11:brown②,⑩)
③Ifthereisstandingwater,󰘰ndtheleakagearea,replacethepart.