EasyManua.ls Logo

Rheem RTGH-RH11DV - Chapter 4: Troubleshooting - Fan Sensor Issues; Er:61 Fan RPM Sensor Abnormality

Rheem RTGH-RH11DV
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
Errorcode Meaning Condition
FanRPMSensorAbnormality
(Automaticrestore)
When the Fan RPM Sensor is
abnormalstate,errorcode61will
appear.
Failureevent
StopalloftheoutputswhenFanRPMSensorisconnectedtoanabnormalstate.
(Refertoinstallationmanual)
Checkpoint
①Checkwiringlineconnectioncarefully.
FanStartCoil(white)ⓔ:connector④
RPMSensor(yellow)ⓓ:connector
GND(blue)ⓒ:connector②
VDD(red)ⓑ:connector③
FanEndCoil(black)ⓐ:connector