5.11 Flushing of chemical dosing systems
To avoid problems in chemical dosing like solidified detergent and blocked piping it’s
very important to flush the system regularly with hot water.
It’s recommended to flush the dosing systems every two weeks and always whenever
the detergent container is changed.
Fill a container with hot tap water and put the detergent suction tubes into the container.
In user’s mode press “Next” –key to find “Chemical dosing rinse”-key, by pressing it the
chemical dosing sytems in use can be flushed. Repeat the flushing 3 times.
Put the suction tubes into the deterg nt container and turn on the pumps once again to
refill the system with the current detergent.
5.12 Set the date and time in user's mode
It's possible to set the date and time also in user's mode by pressing the time window.