EasyManua.ls Logo

Rhymebus RM6E1 Series - User Manual

Rhymebus RM6E1 Series
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VARIABLE FREQUENCY
DRIVE
Operation Manual
RM6E1 series

Table of Contents

Questions and Answers

Summary

PREFACE

SAFETY PRECAUTION

Installation

Covers precautions for installing the drive, including material, location, and temperature.

Wiring

Operation

INTRODUCTIONS

Features

Lists key features of the drive, such as temperature management, special function keys, and communication.

Chapter 1 Cautions Before Installation

1-1 Product Verification

Instructions for verifying the drive's appearance, nameplate, and accessories after receiving it.

1-2 Standard Specifications

Details specifications for single-phase and three-phase series of the drive, including voltage and current ratings.

1-3 COMMON SPECIFICATIONS

Outlines common specifications like control method, frequency setting, and overload protection.

1-4 THE DISASSEMBLED SKETCH OF RM6 E1

Provides a visual breakdown of the drive's components, showing main circuit, fan, and covers.

Chapter 2 Installation and Confirmation

2-1 Basic Equipment

Lists essential components required for the drive's operation, including power source and breakers.

2-2 Environmental Conditions

Specifies environmental requirements for installation, covering location, arrangement, and cleaning.

2-3 Descriptions of Terminal and Wiring Diagram

Explains main circuit and control terminals, wiring diagrams, and input/output signal definitions.

Chapter 3 The Setting of Operation Panel & Remote Controller

3-1 FUNCTIONS OF OPERATION PANEL

Details indicators, keys, and the knob on the operation panel for user interaction.

3-2 FUNCTIONS OF REMOTE CONTROLLER(KP-601 KEYPAD)

Explains the indicators, keys, and knob of the optional KP-601 remote keypad.

3-3 THE OPERATION OF THE OPERATION PANEL AND MONITOR MODE

Describes how to operate the panel, including monitor modes, fault messages, and parameter settings.

Chapter 4 Parameter List

F0 System Parameters

Lists system parameters like software version, parameter locking, and default settings.

F1 Operation Parameters

Covers parameters related to start command, frequency command, display settings, and stop modes.

F2 Frequency Parameters

Details parameters for setting preset speeds, jog speed, acceleration/deceleration times, and frequency limits.

F3 Control Parameters

Explains parameters for holding frequency, stall prevention, motor slip compensation, and DC braking.

F4 Protection Parameters

Outlines parameters for grounding fault, overload protection, drive overheat, and system overload detection.

F5 Multi-function Parameters

Covers analog input/output settings, multi-function terminals, and PID control parameters.

F6 Special Parameters

Details sequential operation control, PID control selection, communication settings, and baud rate.

Chapter 5 Parameter Setting Description

F0 System Parameters

Explains drive information, parameter locking, password settings, and default settings.

F1 Operation Parameters

Describes start command selection, frequency command selection, and stop modes.

F2 Frequency Parameters

Details settings for preset speeds, jog speed, acceleration/deceleration, and V/F patterns.

F3 Control Parameters

Explains holding frequency, stall prevention, motor slip compensation, and voltage boost.

F4 Protection Parameters

Covers motor overload protection, drive overheat, PTC overheat protection, and system overload.

F5 Multi-function Parameters

Details analog input/output, multi-function terminals, and PID control settings.

F6 Special Parameters

Explains sequential operation control modes, PID control selection, and communication settings.

Chapter 6 Communication Description

6-1 KP-601; Modbus Port (RJ-45)

Describes the pinout and connection for the KP-601 keypad and Modbus port.

6-2 The Setting of Communication Parameter

Outlines settings for communication address, baud rate, format, and overtime.

6-3 Communication Protocol

Explains serial data transmission formats (8,N,2; 8,E,1; 8,O,1; 8,N,1).

6-4 Message Format

Details the structure of Modbus messages, including address, OP code, data, and CRC checksum.

6-5 CRC Checksum Algorithm

Explains the algorithm for generating CRC checksum codes for message validation.

6-6 Processing Time of Communication Transmission

Describes the timing for communication transmission between host and drive.

6-7 Communication Troubleshooting

Provides guidance on identifying and resolving communication errors using error codes and descriptions.

6-8 Drive Registers and Command Code

Lists registers for write and read operations, including function settings and error codes.

6-9 Programming Examples - Register and Command

Provides practical examples of host control for drive function settings and read/write operations.

Chapter 7 Operation Procedures and Fault Protection

7-1 Operation Procedures

Step-by-step guide for operating the drive, including wiring, parameter setting, and motor control.

7-2 Fault Protection Display and Troubleshooting

Lists drive error messages, their causes, and troubleshooting steps for common faults.

Appendix A Peripheral Equipment of Drive

1. Specification of product

Details environmental conditions and specifications for using zero-phase radio frequency filters.

2. Wiring for RFI

Provides wiring diagrams for installing RFI filters at the power source and output sites.

Appendix B Selection of AC Reactor(ACL)

a. Suppress the harmonic current...

Explains the function of AC reactors in suppressing harmonic current and improving power factor.

b. When the power capacity...

Guides on when ACL installation is necessary based on power capacity and drive rating.

c. When one of the heater...

Addresses harmonic interference from equipment like SCRs and air compressors, recommending ACL.

d. When multiple drives...

Discusses interference from multiple high-horsepower drives and the need for ACL.

e. When the cable length...

Recommends ACL for long cable lengths or parallel motor connections.

f. The power factor...

States that ACL improves power factor to over 75% when installed at the input.

g. Please select suitable specification...

Refers to a specification list for selecting appropriate ACL based on motor capacity.

h. The outline dimensions...

Shows outline dimensions and specifications for different AC reactor models.

Appendix C Selection of EMC Filter

Recommending specification of EMC filter

Provides guidance on selecting EMC filters based on drive model numbers and rated current.

Appendix D Zero-Phase Radio Frequency Filter Selection

1. Specification of product

Lists specifications for the RM6E1 model, including environmental conditions and filter placement.

2. Wiring for RFI

Provides wiring diagrams for installing RFI filters at the power source and output sites.

Appendix E Selection of Motor

a. Standard Motor

Discusses using 3-phase induction motors, their characteristics, and insulation requirements.

b. Special Motors

Covers synchronous, submersible, and explosion-proof motors, including their specific considerations.

c.Insulation Measurement of Drive and Motor

Details procedures for measuring drive and motor insulation impedance using an insulation tester.

Appendix F Instruction of Drive Charging

Appendix G Dynamic Brake and Resistor

a. RM6 E1 full series...

States that RM6E1 series has a built-in braking transistor and discusses braking resistor options.

b. Braking resistor outline...

Shows the outline of an aluminum case braking resistor.

c. Braking resistor specification

Lists specifications for braking resistors, including dimensions and weight.

d. Braking Resistor List

Provides a list of standard braking resistors and approximate braking torque for various drive models.

e. The Wiring of Braking Resistor

Illustrates wiring diagrams for thermal switches and magnet contactors related to braking resistors.

Appendix H Outline Dimension Drawings

(1) Outline Dimension of Keypad

Shows the external dimensions of the KP-601 keypad.

(2) Overall Dimensions of Drive

Provides overall dimensions for various RM6E1 drive models.

Attachment 1 Setting Memo

Attachment 2 Setting Memo

Attachment 2 Fault Displays

Rhymebus RM6E1 Series Specifications

General IconGeneral
BrandRhymebus
ModelRM6E1 Series
CategoryDC Drives
LanguageEnglish