EasyManuals Logo

Rice Lake 920i Configuration

Rice Lake 920i
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
920i
®
and 882IS/882IS Plus
920i Setpoint Configuration with 882IS/882IS Plus
Manuals and additional resources are available from Rice Lake Weighing Systems at www.ricelake.com/manuals
Warranty information can be found at www.ricelake.com/warranties
NOTE: For additional information about 882IS/882IS Plus and 920i indicators see:
183532 882IS and 882IS Plus Intrinsically Safe Indicator/Controller Technical Manual
67887 920i Programmable Indicator/Controller Technical Manual
WARNINGS:
Some procedures described in this document require work inside the indicator enclosure. These procedures must be performed
by qualified service personnel only.
Do not place fingers into slots or possible pinch points.
When working on components inside the enclosure, ensure the power cord is disconnected from the outlet.
IMPORTANT: Use anti-static protection for grounding and to protect components from electrostatic discharge (ESD) when
working inside indicator or fiber optic converter enclosures.
1. Overview
The 882IS/882IS Plus indicator is capable of controlling setpoint batching on a remote Rice Lake Weighing Systems 920i
weight indicator. This capability enables an industrial batching engine to run in a safe environment controlled by the 882IS/
882IS Plus through a fiber optic cable from a hazardous area. With a special iRite program, the 920i is capable of running as a
serial scale with batching setpoints controlled by the 882IS/882IS Plus indicator.
The 882IS/882IS Plus communicates through fiber optic cables connected to a fiber optic converter. The data is then converted
and transfered via serial cable (RS-232 or RS-422) to the 920i. The 882IS/882IS Plus can configure the value of setpoints 1-10,
given the setpoints are enabled on the 920i, for control of both indicator and external equipment functions. The 882IS/882IS
Plus can control a batch operation that has been set up on a 920i (located in the safe area) and supports:
Batch Start
Batch Stop
Batch Pause
Batch Reset
When setting up a 882IS/882IS Plus with 920i batching systems, the following sections must be followed in order:
Setup Order Page
2. Requirements Page 2
3. Hardware Installation
3.1 920i Jumper Wire Installation
3.2 Wiring Serial Cable from 920i to Fiber Optic Converter
3.3 Connecting Fiber Optic Cable to 882IS/882IS Plus and
Fiber Optic Converter
Page 2
Page 2
Page 3
Page 4
4. Software Configuration
4.1 920i iRite Software Configuration
4.2 920i Setpoint Configuration
4.3 882IS/882IS Plus Fiber Optic Port Configuration
Page 6
Page 6
Page 7
Page 8
5. 882IS/882IS Plus Setpoint Configuration Page 9
6. Batching Operation
6.1 882IS/882IS Plus Setpoint Batching
6.2 920i Batch Operations
Page 10
Page 10
Page 10
7. Reinstall Indicator Covers Page 11
Table 1. Setup Order
PN 215818 Rev A
October 27, 2022

Other manuals for Rice Lake 920i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rice Lake 920i and is the answer not in the manual?

Rice Lake 920i Specifications

General IconGeneral
DisplayLCD
Processor32-bit microprocessor
Communication PortsRS-232, RS-485, Ethernet, USB
Power SupplyAC or DC
Input Voltage100-240V AC, 50/60Hz or 12-24V DC
Operating Temperature-10 °C to 40 °C (14 °F to 104 °F)
EnclosureNEMA 4X/IP66, stainless steel
Load Cell InputSupports up to 4 load cells
CertificationsNTEP, OIML, CE