TECH MODE
B273 5-2 SM
5.1.2 DATA SET-UP
Send Level
Send level sets the level of the transmission signal. The Tx level should normally
be under -12 dBm.
The send fax level is set to the best condition during manufacture. This should not
be changed in the field.
Dial Mode
Select the dialing mode according to the user's line status.
TONE: Electrical type of dial
PULSE: Mechanical type of dial
Modem Speed
Modem speed sets the maximum modem speed. The value of the maximum
modem speed is checked for both transmitter and receiver when the fax connects
with a remote set. The lowest value is used. It is best set at 33.6Kbps (default).
Error Rate
The Baud rate automatically adjusts to 2400 bps when the error rate goes past the
set value. This ensures that the error rate stays below the set value.
You can select the rate between 5% and 10%.
Notify Toner
With this feature enabled, when the toner becomes low the “toner low” information
will be sent to a specified contact point (for example, the service company). After
accessing this menu, select ON. When the LCD-prompts, enter the name and the
number of the contact point, the customer's fax number, the model name, and the
serial number.