SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103 4-52 SM
Output belt 2 HP error 792-21 D
Detected at HP after the time
prescribed to leave the HP had
elapsed (more than 200 pulses) (1st
detection, jam, 2nd detection, SC
error)
-or-
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 3130 pulses) (1st
detection, jam, 2nd detection, SC
error)
• Output belt 2 motor (M402)
connector loose, broken, defective
• Motor overload
• Motor defective
• Output belt 2 HP sensor (S402)
connector loose, broken, defective
• Sensor defective
Stack height error
792-22 D
Stack height sensor remained ON
while moving toward the top.
-or-
The sensor did not go ON within 6
sec. after the motor turned on.
• Stacker motor (M501) connector
loose, broken, defective
• Motor overload
• Stack height sensor (S502)
connector loose, broken, defective
• Sensor defective
Stacker error 792-23 D
Although the stacker was full at the
start and end of stacker operation
with the stacker full (stacker sensors
ON together), no documents were
detected (also when documents were
leaning)
-or-
Although the stacker was detected
full with the stacker stopped, no
documents were detected within 2
sec.
(1st detection jam, 2nd detection SC
error)
• Stacker HP sensor (S501) connector
loose, broken, defective, or sensor
defective
• Stacker height HP sensor (S502)
connector loose, broken, defective,
or sensor defective
• Stacker detect sensor (S504) loose,
broken, defective, or sensor
defective