SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103 4-74 SM
Right Cover Guide Dual Sensor Errors
SC796-29 A
Cover Guide HP Sensor:
Right (S22) and Cover
Guide Open Sensor: Right
(S23) went ON at the same
time.
• Cover Guide HP Sensor: Right (S23)
defective
• Cover Guide Open Sensor: Right (S23)
defective
• Sensor connector loose, broken, defective
Cover Registration HP Error
SC796-30 A
Cover Registration HP Sensor:
Small/Large (S71, S72) did not go ON
within the prescribed time after the
cover horizontal registration motor
turned on.
-or-
Cover Registration HP Sensor:
Small/Large (S71, S72) did not go OFF
within the prescribed time after the
cover horizontal registration motor
turned on.
• Cover Horiztonal Registration
Motor (M31) defective
• Cover Horizontal Registration
Sensor: Small/Large (S71,
S72) defective
• Sensor or motor connector
loose, broken, defective
Sub Grip HP Sensor (S37) Error
SC796-31 A
The sub grip HP sensor did not go ON
within the prescribed time after the sub
grip lift motor turned on to raise the sub
grip unit.
-or-
The sub grip HP sensor did not go OFF
within the prescribe time after the sub
grip lift motor turned on to lower the
sub grip unit.
• Sub Grip Lift Motor (M17)
defective
• Sub Grip HP Sensor (S37)
defective
• Sensor or motor connector
loose, broken, defective
Sub Grip Size HP Sensor (S38) Error
The sub grip size HP sensor did not go ON within the prescribed time after
the sub grip size motor turned on for horizontal adjustment to the paper
size.
-or-
The sub grip size HP sensor was already OFF when the sub grip size
horizontal adjustment started (from the open to closed position).
• Sub Grip Size Motor (S19) defective
• Sub Grip Size HP Sensor (S38) defective
• Motor or sensor connector loose, broken, defective
The sub grip size HP sensor did not go OFF within the prescribed time after
the sub grip size motor turned on to close sub grippers for horizontal
adjustment of the paper size.
-or-
The sub grip size HP sensor was already ON when the sub grip size
horizontal adjustment started (from the close to open position).
SC796-32 A
• Sub Grip Size Motor (S19) defective
• Sub Grip Size HP Sensor (S38) defective
• Motor or sensor connector loose, broken, defective