SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103 4-86 SM
Temperature Detection Error
After adjustment of the glue temperature,
the glue temperature thermistor (S56)
detected a temperature lower than 135C
for more than 10 sec.
Heater (HTR1) defective
Glue thermistor (S56)
defective
SC797-21 B
The glue level thermistor detected a
temperature higher than 170C for longer
than 10 sec. after the glue had warmed
up.
-or-
The glue level thermistor detected a
temperature higher than 100C for longer
than 10 sec. after the glue had warmed
up.
Glue level thermistor (S58)
defective
Protection Circuit Error
SC797-22 B
The thermostat (THSW1) inside the
gluing unit detected an abnormally high
temperature.
Glue heater (HTR1)defective
Thermostat (THSW1)
defective
Glue Surface Error 1
The surface of the glue in the vat did not
reach the lower limit position. This error
occurred when the glue surface was
detected below the lower limit position 4
times in succession during the glue
replenishment cycle.
Glue has clogged in the vat
Glue supply defective
Glue level thermistor (S58)
defective
SC797-23 B
The glue level thermistor could not
detect the glue surface at the upper limit
position: 1) After glue was detected
above the low limit mark, and 2) After 12
glue packets were supplied, and 3) No
glue had been recently applied.
Glue has clogged in the vat
Glue level thermistor (S58)
defective
Glue Surface Error 2
SC797-24 B
Without a glue vat refill, the glue level
thermistor could not detect the level
of the glue below the upper limit (full)
level, even after the application of
25.42 g of glue.
Glue application abnormal (not
applying correctly)
Glue level thermistor (S58)
defective
Glue Level Thermistor (S58) Adjustment Error
One of the following errors occurred in the adjustment data for the glue
level thermistor:
1. Glue level thermistor 1 value (low limit) was out of the range:
128C±14C)
2. Glue level thermistor 2 value (high limit) was out of the range:
142C±10C)
3. Glue level thermistor adjustment value 1 was larger than for
adjustment 1.
SC797-25 B