MO-C1 Training
Slide 89
If the Nozzle Check Pattern is No Good Even
After Three Cleanings and One Flushing
1. Make sure that the ambient temperature and humidity are within the
acceptable range:
Temperature Range: 10°C to 27°C (50 °F to 81°F)
Humidity Range: 15% to 80% Rh
2. Execute print head cleaning once, and then print a Nozzle Check Pattern.
3. If the Nozzle Check Pattern is abnormal, let the machine remain idle for
10 minutes.
4. Execute two more cleanings and one flushing.
Be sure to print a Nozzle Check Pattern after each cleaning and the
flushing.
Any time that you see an unbroken Nozzle Check Pattern, you can stop.
5. If the Nozzle Check Pattern is still not perfect, let the machine remain idle
for 8 hours.
6. Execute three more cleanings and one flushing.
Be sure to print a Nozzle Check Pattern after each cleaning and the
flushing.
Any time that you see an unbroken Nozzle Check Pattern, you can stop