Communication Switch 0B - Not used (do not change the settings)
Communication Switch 0C - Not used (do not change the settings)
Communication Switch 0D
No FUNCTION COMMENTS
0
to
7
The amount of remaining
memory below which
ringing detection (and
therefore reception into
memory) is disabled
(BRO only)
00 to FF (Hex), unit = 2 kbytes
(e.g., 0C[H] = 24 kbytes)
One page is about 24 kbytes.
If this setting is kept at 0, the machine will detect
ringing signals and go into receive mode even if there
is no memory space left. This will result in
communication failure.
(BR1: Do not change the setting.)
Communication Switch 0E
No FUNCTION COMMENTS
0
to
7
Minumum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06[H] = 12 s)
This value is the minimum time that the machine waits
before it dials the next destination.
Communication Switch 0F - Not used (do not change the settings)
Communication Switch 10
No FUNCTION COMMENTS
0
to
7
Memory transmission:
Maximum number of dialing
attempts to the same
destination (BRO only)
01 - FF (Hex) times
(BR1: Do not change the settings.)
Communication Switch 11
No FUNCTION COMMENTS
0
to
7
Immediate transmission:
Maximum number of dialing
attempts to the same
destination
01 - FF (Hex) times
Communication Switch 12
No FUNCTION COMMENTS
0
to
7
Memory transmission:
Interval between dialing
attempts to the same
destination (BRO only)
00 - FF (Hex) minutes
(BR1: Do not change the settings)