Technical Bulletin PAGE: 3/9
Model: Model U-P1 Date: 3-Feb-03 No.: RG071003
Symptom Corrected Version
Default settings for SP2-944-4 and –5 have been changed to reduce the
lubrication mode cycle :
SP2-944-4 : Sheets-1 : [10 to 80/ 30 (old : 20) / 1sheet/step]
SP2-944-5 : Sheets-2 : [10 to 80/ 60 (old : 40) / 1sheet/step]
Euro symbol not printed with PS driver (for details, see Gen
RGene011).
Minor bug corrections.
V2.19
First release.
Display for SP5-
945 (MidThickPaper) deleted, as this setting can be performed in
User Tools.
SP1-920-1 to 3 (PFMtrDelayTime) has been newly added (see table below).
SP2-310 to 2 -314: Some defaults have been changed (see table below).
Default value of SP2-903 (PaperTrans_Low) has been changed from
improve image quality in low-temperature and low-humidity conditions:
Adjusts the paper transfer current applied when the machine is at low temperature.
[0.0 ∼ 70.0 / 1.0 / 0.1 µA/step]
l SP2-905-
01 (paper transfer roller type) has been newly added due to a shape
modification to the paper transfer roller to increase transferability (from 1
st
production).
0: New paper transfer roller type (Drum type),
1: Old paper transfer roller type (straight type)
NOTE:
When updating from v2.18 to v2.19 or later, please check to see that the new
defaults for the following SPs have been applied (new default table below). If they
have not, set SP2-905-01 to a value of 0 and press #.
August production machines
have the drum type installed, therefore it is not necessary to set this to 0 on these
machines.
l
Due to the paper transfer roller modification above, defaults have been chan
for SP2-310-001 to SP2-314-032 (paper transfer current SPs), and SP2-903-
(paper transfer adjustment).
Default for SP2-943 (Discharge Threshold) has been changed from
the minimum setting changed from 13.0 to 9.0.
Note: As with a ll DFU SP modes, please do not adjust the setting.
Adjusts the threshold of discharge. DFU
[9.0 ~ 22.0 / 15.0 / 1.0 g/m
3
/step]
V2.18