8
Important
: In the next step, be sure and lift up the shaft
slowly and gently
. If it is lifted up
too quickly or with too much force, the fusing lamp will be damaged.
6. Lift up the shaft [A] very gently, just enough so that the lower pressure spacer can be
inserted. While holding the shaft up, insert the lower pressure spacer (B0514371)
between the pressure side plate [B] and lower cover.
Note:
Insert the spacer so that the positioning projections can pass through the hole
and cut-outs in the spacer (see the illustrations below).
Bird’s eye view of Fig.1 above:
Projections should
pass through holes
and cut-outs.
Lower pressure spacer
B0514371
Lift up
slightly and
g
entl
y
.
A
B
Positioning
projections