39
Skip keys lock
Communication
ON Prevents LOCKing of the physical buttons while the RD60xx unit is communicating.
OFF LOCKs the physical controls when communicating.
IF OFF,
When the RD60xx is communicating via any interface (Interface-UART or
Interface-USB), the unit’s controls are LOCKed and can only be controlled by the
remote device. (PC, Smartphone App, etc)
IF ON,
The RD60xx unit can be controlled by the remote device OR the controls on the
unit itself.
SkipExitIVSet
Appearance
ON Pressing ON/OFF button will NOT exit Voltage or Current adjustments.
OFF Pressing ON/OFF button will accept and exit Voltage or Current adjustments.
IF ON,
Pressing ON/OFF will toggle the output state only. Any in-process Voltage or
Current adjustments are NOT taken into account and the adjustment setting
cursor remains active.
IF OFF,
Pressing ON/OFF will toggle the output state AND immediately exit, without
saving, any in-process Voltage or Current setting adjustment.
Standby LED
Power Settings
POWER Button Illumination when device turned off (In Standby)
Pulsating Continually sweeps from OFF to full brightness and back.
0% No illumination in OFF state.
5% - 100% Continuous illumination at brightness selected. (5% increments)
All options, except Pulsating, allow the RD60xx to go into a power-saving sleep mode.
(Lowering standby power usage)