OF45175A
OPERATOR’S MANUAL
TWIN STACK
PORTABLE AIR
COMPRESSOR
To reduce the risk of injury, the user
must read and understand the
Operators Manual before using this
product.
!
WARNING:
IN624800AV 1/08

Table of Contents

Questions and Answers

  • D
    Dustin ReeseSep 10, 2025
    Why does my RIDGID Air Compressor run continuously?
    • L
      Lisa MooreSep 10, 2025
      If your RIDGID Air Compressor runs continuously, it could be due to a defective pressure switch, which would need to be replaced. Alternatively, there might be excessive air usage, meaning you need to decrease air usage or the compressor isn't large enough for your requirements.
  • J
    John MooreSep 12, 2025
    Why is the air output lower than normal on my RIDGID OF45175A Air Compressor?
    • J
      Jessica RogersSep 12, 2025
      If the air output of your RIDGID Air Compressor is lower than normal, several factors could be responsible. Loose mounting bolts should be repaired by an authorized service representative. Broken inlet valves may be the cause. A dirty intake filter should be cleaned or replaced, and all connections should be tightened.
  • C
    Christine MartinSep 14, 2025
    Why does the fuse blow or circuit breaker trip repeatedly on my RIDGID OF45175A?
    • Q
      qjohnsonSep 14, 2025
      If the fuses blow or the circuit breaker trips repeatedly on your RIDGID Air Compressor, it could be due to several reasons: 1. The fuse might be the incorrect size, or the circuit could be overloaded. Check for the proper fuse and use a time-delay fuse. Try disconnecting other electrical appliances from the circuit or operate the compressor on its own branch circuit. 2. The unit may be plugged into an extension cord; remove it. 3. A defective check valve or unloader could be the culprit; consider replacing or repairing these components.
  • U
    ucohenSep 16, 2025
    Why does the motor on my RIDGID OF45175A hum but not run properly?
    • B
      Brandon BellSep 16, 2025
      If the motor of your RIDGID Air Compressor hums but cannot run or runs slowly, consider the following potential causes: * Low voltage could be the issue. Check the voltage with a voltmeter. * The unit may be plugged into an extension cord, which should be removed. * There might be a shorted or open motor winding, requiring motor replacement. * A defective check valve or unloader could also be the cause, needing replacement or repair.

Summary

Safety Instructions

Safety Signal Words

Explains the meaning of danger, warning, caution, and notice symbols used in the manual.

Before Using the Air Compressor

Details essential safety precautions to follow before operating the air compressor.

Spraying Precautions

Breathable Air Warning

Important warning that the compressor does not supply breathable air without proper filtering.

Motor Specifications and Electrical Requirements

Power Supply and Motor Specifications

Details the voltage, amperage, frequency, phase, and RPM of the compressor motor.

General Electrical Connections

Provides guidelines for safe electrical connections, grounding, and circuit protection.

Thermal Overload Protector

Unpacking and Checking Contents

Operating Your Air Compressor

Maintenance

Tank Maintenance and Components

Troubleshooting

RIDGID Air Compressor Limited Three Year Warranty

RIDGID OF45175A Specifications

General IconGeneral
Power SourceElectric
Tank Capacity4.5 Gallons
Maximum Pressure175 PSI
SCFM @ 90 PSI5.1
Pump TypeOil-Free
Voltage120V
TypePortable
Max Pressure175 PSI
CFM at 90 PSI5.1
HP1.6
Amps15 Amps
Noise Level78 dBA