EasyManua.ls Logo

Riello 40 F10 User Manual

Riello 40 F10
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
2902554 (2) - 01/2009
Installation & Operating Manual
Single stage operation oil burner
CODE MODEL TYPE
3726313 F10 WITH MANUAL AIR SHUTTER 263T
NON-RETROFIT APPLICATIONS
If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow
the installation and set-up instructions supplied with the heating unit, as settings may differ from
those shown in this manual.
- The following pages contain information, descriptions and diagrams for the proper installation
and wiring of the burner. Please read carefully before attempting final installation.
- This manual is to remain with the final installation designation. It is the installer’s responsibility to en-
sure that the burner installation and operation instructions mentioned in this manual are followed and
operated within local code authority limits.
WARNING

Other manuals for Riello 40 F10

Question and Answer IconNeed help?

Do you have a question about the Riello 40 F10 and is the answer not in the manual?

Riello 40 F10 Specifications

General IconGeneral
BrandRiello
Model40 F10
CategoryBurner
LanguageEnglish

Summary

Non-Retrofit Applications

Installation in Packaged Units

Follow specific unit instructions as settings may differ from this manual.

Parts List

Technical Data

Dimensions

Physical dimensions of the Riello 40 F10 burner, including A, B, C, D, E, F measurements.

Specifications

Technical specifications including fuel type, firing rate, effective output, voltage, power, motor, capacitor, pump pressure, control, and transformer.

Mounting Flange Dimensions

Dimensions related to mounting the burner flange, including A, B, C, D measurements.

Oil Burner Components Identification

F10 Burner Components

Identification and numbering of individual components of the F10 burner model.

Serial Number Identification

Explanation of the Riello 15-character serial number format and its components.

Initial Set-up

Air Tube Assembly to Burner Chassis

Mounting the Burner to Boiler or Furnace

Method 1 - Universal Mounting Flange

Step-by-step instructions for mounting the burner using a universal flange.

Method 2 - Semi-Flange Collar

Method 3 - Pedestal Mount

Electrical Connections

Application Field Wiring

Remote Sensing of Safety Lockout

Explanation of remote lockout sensing via terminal 4 on the sub-base and its implications.

Nozzle Placement

Insertion/Removal of Drawer Assembly

Electrode Setting

Turbulator Setting

Oil Line Connections

Single Line (Gravity Feed System)

Two Line (Lift System)

Pump Purge

Single Line (Gravity Feed System)

Procedure for purging the oil pump in a single line system.

Two Line (Lift System)

Procedure for purging the oil pump in a two line system.

Setting the Air Adjustment Plate

Combustion Chamber

Non-Retrofit Applications

Instructions for burners installed in packaged units; settings may differ from this manual.

For Canada Precautions

Air for Combustion

Ensuring adequate air supply for combustion in Canada, following local ordinances or CSA B139.

Chimney

Requirements for chimney sufficiency, cleanliness, and obstructions in Canada.

Oil Filter

Requirements for external oil filter replacement and cleaning in Canada.

Draft

Maintaining pressure in the combustion area close to zero in Canada.

Electrical Connections

Electrical connection standards according to C.E.C. Part I and local codes in Canada.

Control Burner Operation

Explaining burner operation and leaving owner's sheet in Canada.

Fire Extinguisher

Requirement for an approved fire extinguisher if mandated by local codes in Canada.

For USA Precautions

Air for Combustion

Ensuring adequate air supply for combustion in the USA, following local ordinances or NFPA #31.

Chimney

Requirements for chimney sufficiency, cleanliness, and obstructions in the USA.

Oil Filter

Requirements for external oil filter replacement and cleaning in the USA.

Draft

Maintaining pressure in the combustion area close to zero in the USA.

Electrical Connections

Electrical connection standards according to NEC and local ordinances in the USA.

Control Burner Operation

Explaining burner operation and leaving owner's sheet in the USA.

Fire Extinguisher

Requirement for an approved fire extinguisher if mandated by local codes in the USA.

Spare Parts

Spare Parts List