Page #1 background image
VLT (01)
VLT (13)
VLT (14)
B
A
O
E
E
G
1
N G
F
F
PN
PN
G
2
F
F
F
B
A
F
E
O
D
C
B
F
B
b
Q
Q
b
Q
A
E
O
F
VLT
VLT 6
VLT 10
VLT 15
VLT 25
VLT 40
VLT 60
- 1 -
Vakuumpumpen
Betriebs- und Serviceanleitung
Inhaltsverzeichnis:
Ausführungen - 2 -
Beschreibung - 2 -
Bestimmungsgemäße
Verwendung - 2 -
Aufstellung - 2 -
Installation - 2 -
Inbetriebnahme - 3 -
Wartung und Instand-
haltung - 3 -
Störungen und
Abhilfe - 4 -
Anhang - 4 -
Ersatzteillisten: E 280
E 280/13
E 280/14
E 280/20
B 280
2.5.2001
Werner Rietschle
GmbH + Co. KG
Postfach 1260
79642 SCHOPFHEIM
GERMANY
07622 / 392-0
Fax 07622 / 392300
E-Mail: info@rietschle.com
http://www.rietschle.com
Question and Answer IconNeed help?

Do you have a question about the Rietschle Pico VLT 40 and is the answer not in the manual?

Rietschle Pico VLT 40 Specifications

General IconGeneral
BrandRietschle
ModelPico VLT 40
CategoryWater Pump
LanguageEnglish

Summary

Pump Ranges and Setup

Description

Details features like vacuum connection, exhaust silencer, and micro-fine filter.

Directed Suitability

Specifies industrial use, closed system evacuation, and permanent vacuum range.

Setting Up and Installation

Covers pump placement, required clearances, horizontal installation, and electrical connections.

Safety Warnings

Includes precautions for hot surfaces, temperature limits, noise, and electrical installation.

Initial Operation

Pump Start-up Check

Check direction of rotation by briefly switching the pump on and off.

Suction Pipe Connection

Connect suction pipe after initial start-up check; avoid long/small bore pipes.

Vacuum Regulating Valve

Adjust vacuum level using the regulating valve (C) as per symbols.

Maintenance and Servicing

Lubrication

VLT pumps have sealed, lifetime-greased bearings and require no lubrication.

Air Filtration

Filter cartridges (e) require cleaning or replacement to maintain pump capacity.

Blade Inspection and Replacement

Inspect blades for wear based on operating hours and replace if minimum height is reached.

Troubleshooting and Appendix

Motor Starter Issues

Addresses issues like tripping, incorrect connections, or settings on the motor starter.

Suction Capacity Problems

Covers blocked filters, long pipework, leaks, and worn/damaged blades.

Overheating Issues

Troubleshoots high operating temperatures due to ambient conditions or restricted cooling airflow.

Abnormal Noise

Identifies causes of noise such as worn pump cylinders, noisy regulating valves, or damaged blades.

Repair and Site Operations

Guidelines for on-site repairs, including electrical disconnection and consulting service agents.

Lifting, Transport, and Storage

Instructions for lifting pumps, transport, and proper storage conditions.

Spare Parts Lists

Lists available spare parts and their corresponding pump models.