Appendix RIGOL
DG800 Performance Verification Guide
3
Harmonic Distortion Test
Frequency
Setting
Value
Setting
Measurement
Value
Calculation
Result
[1]
Specification Pass/Fail
10MHz
Waveform:
Sine
Amplitude:
0dBm
Offset: 0V
dc
Base waveform:
<-55dBc
2
nd
order
harmonic:
20MHz
[2]
Base waveform:
<-50dBc
2
nd
order
harmonic:
30MHz
[3]
Base waveform:
<-40dBc
2
nd
order
harmonic:
Note
[1]
: Calculation result = 2th order harmonic measurement value - base waveform measurement value.
Note
[2]
: Only applicable to DG822, DG821, DG832 and DG831.
Note
[3]
: Only applicable to DG832 and DG831.
Spurious Signal Test
Output
Frequency
Start
Frequency
Stop
Frequency
A A-0dBm Specification Pass/Fail
5MHz 0Hz 30MHz <-60dBc
10MHz 0Hz 50MHz <-60dBc
20MHz
[1]
0Hz 100MHz <-54dBc
30MHz
[2]
0Hz 150MHz <-48dBc
Note
[1]
: Only applicable to DG822, DG821, DG832 and DG831.
Note
[2]
: Only applicable to DG832 and DG831.
Rise/Fall Time Test
Waveform Setting Measurement Value Specification Pass/Fail
Square
Frequency: 1kHz
Amplitude: 1Vpp
Offset: 0V
dc
Rise Time
Typical (1 Vpp, 1
kHz)
9 ns
Fall Time

Other manuals for Rigol DG800 Series