EasyManuals Logo

Rigol DS1054Z User Manual

Rigol DS1054Z
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
RIGOL Contents
XX MSO1000Z/DS1000Z User’s Guide
To Use the Built-in Help System ............................................................. 1-26
Chapter 2 To Set the Vertical System ................................................. 2-1
To Enable the Analog Channel ................................................................. 2-2
Channel Coupling ................................................................................... 2-2
Bandwidth Limit ..................................................................................... 2-3
Probe Ratio ........................................................................................... 2-3
Waveform Invert .................................................................................... 2-4
Vertical Scale ......................................................................................... 2-4
Amplitude Unit ....................................................................................... 2-5
Channel Label ........................................................................................ 2-5
Delay Calibration of the Analog Channel ................................................... 2-7
Chapter 3 To Set the Horizontal System ............................................ 3-1
Delayed Sweep ...................................................................................... 3-2
Time Base Mode .................................................................................... 3-3
YT Mode ......................................................................................... 3-3
XY Mode ......................................................................................... 3-3
Roll Mode ....................................................................................... 3-5
Chapter 4 To Set the Sample System ................................................. 4-1
Acquisition Mode .................................................................................... 4-2
Normal ........................................................................................... 4-2
Peak Detect .................................................................................... 4-2
Average .......................................................................................... 4-2
High Resolution ............................................................................... 4-3
Sin(x)/x ................................................................................................. 4-4
Sample Rate .......................................................................................... 4-4
Memory Depth ....................................................................................... 4-6
Antialiasing ............................................................................................ 4-7
Chapter 5 To Trigger the Oscilloscope ................................................ 5-1
Trigger Source ....................................................................................... 5-2
Trigger Mode ......................................................................................... 5-3
Trigger Coupling..................................................................................... 5-4
Trigger Holdoff ....................................................................................... 5-5
Noise Rejection ...................................................................................... 5-5
Trigger Type .......................................................................................... 5-6
Edge Trigger ................................................................................... 5-7
Pulse Trigger ................................................................................... 5-8
Slope Trigger ................................................................................. 5-10
Video Trigger................................................................................. 5-13
Pattern Trigger .............................................................................. 5-15
Duration Trigger ............................................................................ 5-17
TimeOut Trigger (Optional) ............................................................. 5-19
Runt Trigger (Optional) .................................................................. 5-21
Window Trigger (Optional) .............................................................. 5-23
Delay Trigger (Optional) ................................................................. 5-25
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Other manuals for Rigol DS1054Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1054Z and is the answer not in the manual?

Rigol DS1054Z Specifications

General IconGeneral
Channels4
Bandwidth50 MHz
Sample Rate1 GSa/s
Memory Depth24 Mpts
Display7 inch TFT LCD (800x480)
Vertical Sensitivity1 mV/div to 10 V/div
Time Base Range5 ns/div to 50 s/div
Vertical Resolution8 bits
Trigger TypesEdge, Pulse, Video, Slope
ConnectivityUSB Host, USB Device, LAN
Input Impedance1 MΩ
Power Supply100-240 VAC, 45-440 Hz