Ring Alarm Keypad User Manual
Proximity Display Timeout : Timeout in seconds
when proximity is detected and no input is received
Button Press Display Timeout : Timeout in seconds
when any button is pressed, but a sequence is not
completed and buttons are no longer being pressed
Status Change Display Timeout: Timeout in seconds
when indicator command is received from the hub to
change status
Security Mode Brightness: Adjusts the
brightness of the security mode buttons
Key Backlight Brightness: Adjusts the brightness of
the keypad backlight. Used for Key Backlight LEDs
only
Available settings: 0-100%
Ambient Light Sensor Level: Light threshold where
keypad will stop backlighting if higher than
Proximity On/OFF: Turn On and Off the Proximity
Detection.
0 = proximity sensor off
1 = proximity sensor on
Ramp Time Config: Ramp time in units of ten
milliseconds each to turn the LEDs on/off.
Applies to all LEDs on the keypad
Low Battery Threshold - The percentage level at
which the display would turn on the yellow
battery indicator (whenever the display is on).