EasyManua.ls Logo

ring Z-Wave - Association Command Class; Configuration Command Class

ring Z-Wave
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ring Alarm Outdoor Siren User Manual
Date:
Version: 0.1
Page: - 5 -
Association Command Class
Max Nodes
Description
0x05
1. Notification Report
a. See notification CC section for notifications that are sent
2. Battery Report
3. Device Reset Locally Notification
Configuration Command Class
The sensor has the following supported configuration parameters.
Parameter
Number
Description
Number
of
Bytes
Default
Min
Max
Format
1
Heartbeats:
This parameter is the number
minutes between heartbeats.
Heartbeats are automatic
battery reports on a timer
after the last event.
1
70
(0x46)
1 (0x01)
70 (0x46)
0x01
Unsigned
2
Number of application level
retries attempted for
messages either not ACKed
or messages encapsulated
via supervision get that did
not receive a report.
1
1 (0x01)
0 (0x00)
5 (0x05)
0x01
Unsigned
3
Application Level Retry Base
Wait Time Period:
The number base seconds
used in the calculation for
sleeping between retry
messages.
1
5 (0x05)
1 (0x01)
60 (0x3C)
0x01
Unsigned

Other manuals for ring Z-Wave

Related product manuals