Ring Alarm Outdoor Siren User Manual
Date:
Version: 0.1
Page: - 7 -
Parameter
Number
Description
Number
of
Bytes
Default
Min
Max
Format
10
Blinking Logo Ramp time
Ramp time in units of ten
milliseconds each to turn the
Logo LED on/off when
Blinking
1
50
(0x32)
0 (0x00)
255 (0xFF)
0x01
Unsigned
Notification Command Class, V8
Sensor Condition
Command Class and Value
Association
Group
AC mains power reconnected
Notification Report
Type: 0x08 Power Management
State: 0x03 AC mains reconnected
1 (Lifeline)
AC mains power disconnected
Notification Report
Type: 0x08 Power Management
State: 0x02 AC mains disconnected
1 (Lifeline)
Watchdog Notification
Notification Report
1 (Lifeline)

Other manuals for ring Z-Wave