Ring Alarm Outdoor Siren User Manual
Date:
Version: 0.1
Page: - 9 -
Sensor Condition
Command Class and Value
Association
Group
Power On Reset
Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied
1 (Lifeline)
Brownout
Notification Report
Type: 0x08 Power Management
Event: 0x05 Voltage Drop/Drift
1 (Lifeline)
Pin Reset (soft reset)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAB
1 (Lifeline)
Dropped Frame
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAD
1 (Lifeline)
Tampered
Notification Report
Type: Home Security 0x07
State: Tampering Product Covering Removed 0x03