4 Rinnai Circ-Logic™ with Grundfos Kit
Rinnai Circ-Logic™ Descripon
Rinnai
Temperature
Setting
°F
Typical Pump ON
Intervals*
(minutes)
Economy
Mode
Comfort
Mode
140 31 15
135 31 15
130 31 15
125 31 15
120 31 15
115 35 18
110 42 21
108 45 22
106 49 24
104 54 27
102 60 30
100 68 34
98 79 39
* The pump will cycle on at these
calculated intervals which are based on
the temperature seng, insulaon, and
esmated heat loss in the system. The
values for your installaon may vary.
How It Works
DIP switches (SW2 - white switches, #4, #8) should be set
correctly for recirculaon and mode. The Rinnai water heater
should be turned on.
Pump recirculaon begins when the water heater is turned on.
The Rinnai inlet and outlet thermistors measure the water
temperature.
The water heater produces hot water at the temperature
seng. If the inlet thermistor detects abnormal temperature
then diagnosc code 51 is generated and the pump will turn o.
When the return water temperature reaches approximately 15°
F (8.3°C) below the temperature seng, the water heater and
pump will turn o.
The cycle will start at the approximate me interval in the table.
The cycle stops based on the temperature thermistor readings.
The Logic has two modes of operaon: Comfort and Economy.
Economy Mode
Economy Mode uses longer me intervals (about twice as long
as Comfort Mode) and can be used for two purposes: to reduce
the energy consumpon required to keep the loop warm and/or
to maintain temperature in a loop that is well insulated.
Economy Mode operates as follows:
Less energy consumed due to fewer pump cycles
Pump cycles on every 31 to 79 minutes (see table)
The me intervals are based on the assumpon that the
loop is insulated.
Comfort Mode
Comfort Mode has shorter me intervals and can be used to
either ensure the loop is always kept hot or to cope with a loop
that has a high degree of heat loss due to lack of insulaon, or
pipes that run through a concrete slab, etc. Comfort Mode
operates as follows:
Higher energy consumpon due to more pump cycles
Pump cycles on every 15 to 39 minutes (see table)
The me intervals are based on the assumpon that the
loop IS NOT insulated.