008082013GW
This can occur when PARA 84 has been
changed to 20 and the field installed jumper is
loose or removed.
212˚F is the default temperature setting for
parameter 84. Verify to see if the temperature
setting for this parameter is set higher than
the default. If so, inspect vent system for
blockage.