Do you have a question about the Rinnai E110CP and is the answer not in the manual?
Type | Condensing Boiler |
---|---|
Model | E110CP |
Heating Capacity/Maximum Input | 110, 000 BTU/h |
Minimum Input | 22, 000 BTU/h |
Output BTU/h | 110, 000 BTU/h |
Energy Star Certified | Yes |
Modulation Ratio | 5:1 |
Heat Exchanger Material | Stainless Steel |
Venting | Direct Vent |
Water Connections | 3/4" NPT |
Fuel Type | Propane |
Mounting | Wall-mounted |
Warning about fire or explosion if instructions are not followed exactly, causing property damage, injury, or death.
Steps to take if you smell gas: do not light, do not touch switches, use neighbor's phone.
Defines the boiler's purpose for heating water for central heating and domestic hot water systems.
Explains terms like DANGER, WARNING, CAUTION, NOTICE and their associated risk levels.
Instructions before operating, including checking for gas and not attempting manual ignition.
Step-by-step guide for operating the boiler, including power, thermostat, and gas valve settings.
Introduction to the Rinnai Q boiler, its features like room sealing, condensing, and modulating central heating.
Details about the integrated control system, outdoor sensor, and optional room thermostat (RS100).
Explanation of the function buttons on the boiler control panel, including ON-OFF, CH, DHW, and Pump buttons.
Description of the Mode-button (for service personnel) and the Reset-button for fault recovery.
Explanation of the 'Good' and 'Technical' readouts on the boiler display and how to switch between them.
List of codes indicating the boiler's operational status, such as no heat demand or ignition phase.
Details on the ideal water pressure range (22-25 PSI) for optimal boiler function.
Explanation of 'FILL' and 'HIGH' messages on the display indicating low or high water pressure.
Procedure for filling the central heating system with potable water and de-aeration.
Information on the automatic de-aeration program that runs after system replenishment.
Instructions on how to turn off the boiler for normal operation or for a holiday period.
Procedure for re-setting the central heating system after it has been switched off.
Explanation of error (E) and blocking (BL) codes displayed when the boiler detects a fault.
Instructions for periodic cleaning of the condensate collection and disposal system.
Statement that maintenance or changes to the appliance must only be performed by a qualified technician.
Information on where to find the warranty conditions, typically supplied with the boiler.