EasyManua.ls Logo

Rinnai REB-KBI2424FF - User Manual

Rinnai REB-KBI2424FF
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Gas-red, condensing, modulating wall-hung
boilers, with adjustable power, sealed chamber,
forced ow with WiFi room thermostat
User and installation manual
REB-KBI2424FF - Zen I24 - Condensing ZI24
REB-KBI2929FF - Zen I29 - Condensing ZI29
REB-KBI3535FF - Zen I34 - Condensing ZI34
Free initial commissioning:
after the product is installed call the green number
a Rinnai authorized technician will provide a free commissioning of the boiler
and will activate the product warranty.
MENU
AUTO ON
OFF
TIMER
ENERGY
MONITOR
SAVE
PUSH

Questions and Answers

  • C
    Cynthia BrownSep 23, 2025
    How to fix Fail 4 on Rinnai Boiler?
    • C
      Cheryl StephensSep 23, 2025
      To address Fail 4 on your Rinnai Boiler, complete the registration of the WiFi command within 10 minutes.
  • A
    alexis43Aug 25, 2025
    What to do if I smell gas coming from my Rinnai Boiler?
    • A
      Alexis PhillipsAug 25, 2025
      If you smell gas, immediately stop the Rinnai Boiler and gas supply. Open all windows and doors to ventilate the area. Do not operate any appliances to prevent potential explosions. Contact your gas supplier and regularly inspect the gas pipes and shut-off valve for leaks.
  • J
    Jonathan MooreAug 25, 2025
    Why does my Rinnai REB-KBI2424FF Boiler have ignition failure?
    • C
      Cynthia MaloneAug 26, 2025
      If your Rinnai Boiler fails to ignite, there are several potential causes: 1. Check if the boiler is properly plugged into an outlet with the correct voltage. 2. Ensure the set temperature on the display is higher than the current temperature. 3. If error code 11 is displayed, turn the boiler off and then on again. 4. Verify that the gas supply valve is open, ensuring gas is available to the boiler.
  • T
    Timothy CarrollAug 27, 2025
    Why is there no hot water coming from my Rinnai REB-KBI2424FF Boiler?
    • K
      Kimberly LarsonAug 27, 2025
      If there is no hot water from your Rinnai Boiler, consider these possible causes: * Ensure the DHW (Domestic Hot Water) mode is active by pressing the DHW button on the remote control. * Confirm there is a water supply to the boiler and wait for water availability. * Check that the water pressure is not too low, as the boiler requires a minimum flow rate of 2.3 liters per minute to start. * Make sure the cold water supply valve is fully open.
  • C
    Christopher Wong DDSSep 23, 2025
    What does error 02 mean on my Rinnai REB-KBI2424FF?
    • J
      Jay GomezSep 23, 2025
      If Error 02 appears on your Rinnai Boiler, which indicates an error in the reset function, press the button CH (or DHW) twice to deactivate and re-activate the function.
  • R
    Richard DiazSep 13, 2025
    What does error 90 mean on my Rinnai Boiler?
    • S
      sharpmarcusSep 13, 2025
      If Error 90 appears on your Rinnai Boiler, it indicates an abnormal rotation of the combustion fan. Press the CH button twice to turn off and on the function.
  • J
    Justin AnthonySep 12, 2025
    What does error 71 mean on my Rinnai REB-KBI2424FF?
    • C
      Chad LewisSep 12, 2025
      If Error 71 is displayed on your Rinnai Boiler, it indicates a solenoid gas valve failure. Press the CH (or DHW) button twice to turn off and on the function. If the error code remains, contact Rinnai technical assistance.
  • C
    Christopher LloydSep 12, 2025
    What does error 72 mean on my Rinnai Boiler?
    • C
      Christopher GarnerSep 12, 2025
      If Error 72 is displayed on your Rinnai Boiler, it indicates a lack of water. Press the CH (or DHW) button twice to turn off and on the function. If the error code remains, contact Rinnai technical assistance.
  • G
    George HerringSep 4, 2025
    What does error 61 mean on my Rinnai REB-KBI2424FF Boiler?
    • H
      Heather PadillaSep 4, 2025
      If your Rinnai Boiler displays Error 61, it signals a combustion fan failure. Verify that the exhaust system is not obstructed. Turn the boiler off and on; if the error code persists, contact Rinnai technical assistance.
  • J
    Joshua WardSep 2, 2025
    What does error 16 mean on my Rinnai Boiler?
    • C
      Corey MillerSep 2, 2025
      If your Rinnai Boiler displays Error 16, it indicates CH overheating. Ensure at least one thermostatic valve is open, vent the air in the heating circuit, and clean the return line filter of the CH.

Rinnai REB-KBI2424FF Specifications

General IconGeneral
CategoryBoiler
BrandRinnai
ModelREB-KBI2424FF
Fuel TypeNatural Gas
Water Connections3/4 inch
Gas Connection1/2 inch
Flue Diameter60/100 mm
Temperature Range30 - 80°C
TypeCombi Boiler
Efficiency95% AFUE

Related product manuals