REU-VR2626WB (B26) /REU-VR2426WS (S26) /REU-VRM2626WG (INF26) - 4 - Issue 3 - 13/11/14 ©Rinnai
Rinnai Model Number
REU-VRM2626WG / REU-VR2626WB
Type of appliance Temperature controlled continuous flow gas hot water system
Exhaust system Fan Forced
Installation External
Dimensions Width - 350 mm
Height - 530 mm
Depth - 194 mm
Weight 16 kilograms
Gas consumption (Min. / Max.) Natural gas: 23~199 MJ/hr
Propane gas: 23~199 MJ/hr
Output (kW) (Maximum) 45 kW
Connections Gas connection - R3/4 (20A)
Cold water connection - R3/4 (20A)
Hot water connection - R 3/4 (20A)
Ignition system Direct electronic ignition
Electrical consumption Normal - 45 W
Standby - 2 W (with 1 water controller)
Anti-frost protection - 90 W
Delivery temperature 40°C, 42°C, 50°C, 55°C, 60°C, 65°C, 75°C
(set by combination of dip switches on PCB)
Water flow control Water flow sensor, electronic water flow control device
Maximum hot water capacity raised @
25°C
26 L/min
Water pressure required to achieve
maximum hot water capacity
180 kPa
Maximum water flow 26 L/min.
Water pressure required to achieve
maximum water flow
180 kPa
Minimum water flow for operation 2.4 L/min.
Power supply Appliance - AC 240 Volts 50 Hz
Water controller - DC 12 Volts
Water controllers (optional)
A maximum of 4 water controllers can be fitted. Any combination of
deluxe, universal and wireless controllers can be used with the following
limitations:
Only ONE master controller can be installed. This can be a MC-100V, a
MC-91Q (when programmed as a mater controller) a MC-503RC water
controller.
Up to TWO BC-100V water controllers can be installed.
The FOURTH water controller in any installation MUST be a
MC-503RC or a MC-91Q.
Water Controller Cable Cables are supplied with water controllers. Alternatively, two core
sheathed (double insulated) flex with minimum cross sectional area of 0.5
m² may be used. Maximum individual cable runs should not exceed 50 m.