Page #48 background imageLoading...
Page #48 background image
Reference Manual V1.19 Software Versions 4.xx
Page 46 003R-682-119
(Reset Printed
Consecutive
Number)
I.LOCK
(Print Interlock)
Sets the type of printing interlock to be used. Options:
NONE
MOTION: Printing is enabled every time the scale becomes stable.
RET.Z: Printing is enabled after the scale has returned to zero and
is stable.
Default: NONE
S.RESP
(Simple Response)
Use this option to set if the indicator responds or not when serial type is
set to simple network. Options:
OFF
ON
Default: OFF

Table of Contents

Other manuals for Rinstrum R320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum R320 and is the answer not in the manual?

Rinstrum R320 Specifications

General IconGeneral
CategoryAccessories
Excitation Voltage5 VDC
TypeIndicator
Display20 mm high
Power12-24 V DC
Operating Temperature-10°C to +50°C
Load Cell Connection4-wire
Communication PortsRS-232, RS-485

Related product manuals