4. OPERATING INSTRUCTIONS
ﻞﻴﻐﺸﺘﻟا تﺎﻤﻴﻠﻌﺗ
4./5
Hydraulic gearcase – Generator set
220 V
Be sure that the power source has
the requested voltage.
Do not use a power source
subject to frequent overvoltage
(maximum admissible: +10% of
the nominal tension).
Use a voltage stabilizer.
PERMITTED EXTENSIONS:
The extensions refer to the plugging of the various
components (heating plate + hydraulic gearcase + facer)
to one single multiple socket.
BASIC 160 V0
220 V
Cable section [ mm
2
] 1,5 2.5
Cable maximum length [ m ] 50 75
BASIC 200 V0
220 V
Cable section [ mm
2
] 1,5 2.5
Cable maximum length [ m ] 25 50
BASIC 250 V1
220 V
Cable section [ mm
2
] 1,5 2,5
Cable maximum length [ m ] 25 50
BASIC 315 V1
220 V
Cable section [ mm
2
] 2,5 4
Cable maximum length [ m ] 25 50
BASIC 355 V0
220 V
Cable section [ mm
2
] 4 6
Cable maximum length [ m ] 25 50