EasyManua.ls Logo

Riva-flo GP40 User Manual

Riva-flo GP40
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IMPORTANT
Please attach your sales invoice/docket here as proof of purchase should warranty service
be required.
Please do not return Warranty - Retain for your records.
Purchased From .............................................................................................. ........................
Purchase Date..................................... Serial No.............................. Model No........................
L100169-0615
© information contained here-in remains the property of Pentair Water Pty Ltd. Any reproduction,
display, publication, modication or distribution is strictly prohibited without the prior written
permission of Pentair Water Pty Ltd.
Disclaimer: Every endeavour has been made to publish the correct details in this owner’s manual.
No responsibility will be taken for errors, omissions or changes in product specications. Pentair
Water reserves the right to change specications
Pacific
Pentair Water Australia Pty Ltd
Australia
1-21 Monash Drive
Dandenong, Victoria, Australia
Tel: 1300 137 344
Email: au.sales@pentair.com
Pentair Water New Zealand Ltd
Christchurch, New Zealand
Tel: 0800 654 112
Email: nz.sales@pentair.com
OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor for the correct advice before proceeding with the
installation or operation of this product.
Jet Assisted
Garden Pump
GP40
We recommend, for additional protection,
the pump to be supplied from socket
outlet protected by a Residual Current
Device RCD (also known as an Earth
Leakage Circuit Breaker ELCB) with a
maximum rated residual current of 30mA.

Questions and Answers:

Riva-flo GP40 Specifications

General IconGeneral
BrandRiva-flo
ModelGP40
CategoryWater Pump
LanguageEnglish

Summary

Pentair Water Product Warranty

Spare Parts

Details on the availability and supply of spare parts for Pentair Water products.

How to Get Service

Instructions on how to claim warranty service, including required documentation and procedures.

Limitation of Implied Warranties

Specifies limitations on implied warranties, such as merchantability and fitness for a particular purpose.

Exclusion of Damages

Details limitations on Pentair Water's liability for damages, including consequential and incidental losses.

Effective Law

Outlines the governing law and specific legal rights applicable to the warranty in different regions.

Terms and Conditions Applicable Internationally

International warranty terms, typically covering a 12-month period for parts from the first consumer purchase.

Terms and Conditions Applicable in Australia and New Zealand

Warranty terms specific to Australia and New Zealand, including consumer protection legislation.

Installation

Electrical Installation Standards

Guidance on electrical installation requirements, referencing national wiring rules for specific product classes.

Installation Advice

General advice for users unfamiliar with pump equipment installation, recommending expert consultation.

Freezing Conditions

Warning about freezing conditions damaging the unit and advice on prevention or disconnection.

Electrical Isolation

Instruction to ensure the pump is electrically isolated from the supply during installation and service.

Fluid Compatibility

Specifies that the pump is for clean water use only, cautioning against abrasive, corrosive, or explosive fluids.

Safety Precautions

Warning that incorrectly installed equipment may cause severe injury or property damage.

Motor Heat Hazard

Advisory on motor heat, fire risk from debris, and burn hazard during handling, mentioning thermal overload.

Preparation for Installation

Guidance on inspecting the pump for shipping damage and ensuring suction piping is free of air leaks.

Troubleshooting

Pump Runs Intermittently

Common causes and remedies for a pump that cycles on and off frequently during operation.

Poor Performance

Diagnosing and resolving issues related to low pressure or reduced flow rate from the pump.

Pump Does Not Start

Troubleshooting steps for when the pump fails to initiate operation, checking power and internal faults.

Pump Will Not Stop

Addressing the issue where the pump continues to run despite no open taps or pressure demand.

No Water From Pump

Steps to diagnose and fix problems when the pump is not delivering any water.

Pump Does Not Produce Enough Pressure

Resolving issues where the pump fails to build adequate pressure in the system.

Operation

Start-up Procedure

Instructions for the initial start-up and operation of the pump, including priming and pressure controller interaction.

Voltage Limits

Warning about operating the pump outside specified voltage limits and potential consequences.

RCD Protection Recommendation

Recommendation to use a Residual Current Device (RCD) for additional protection against electric shock.

Manual Requirement

Requirement for the operator or owner to read and follow this manual for safe operation.

Fluid and Environment Compatibility

Guidance on suitable fluids and environments for pump operation, avoiding hazardous conditions.

Motor Heat and Burn Hazard

Information on motor operating temperatures, fire risks, and burn hazards during handling.

Do Not Run Pump Dry

Critical instruction to ensure the pump is always filled with water before operation to prevent damage.

Service and Maintenance

Qualified Personnel Requirement

Statement that pump servicing should only be performed by qualified personnel.

Electrical Safety During Servicing

Instruction to turn off power and remove plug before working on the pump or motor.

Hot Liquid Hazard

Caution regarding hot liquids and the need to release pressure carefully before servicing.

General Care and Maintenance

Advice on long-term storage, periodic checks for pressure and power absorption to prevent failures.