9
8
7
CARE AND CLEANING
(CONT.)
Wrap cord around the cord wrap on
bottom of steamer.
Wrap flexible steam hose around top
of steamer base and slide nozzle
down onto storage hook.
TROUBLESHOOTING
PROBLEM
Unit won’t steam.
Not enough steam.
Flexible steam hose
drips and/or leaks.
Steamer leaves water
spots on clothing.
Flexible steam hose
emits a gurgling
noise.
PROBABLE CAUSE
• Make sure there is water in the water tank and
unit is plugged in and switched to ON (I)
position.
• Water deposits have built up in unit. See “Care
and Cleaning” section.
• Do not hold the steam handle/nozzle too low for
more than 20 seconds, or steam will condense
into water inside the hose and may block nor-
mal steam flow. Periodically lift steam nozzle/
handle as high as possible to let any condensa-
tion in flexible steam hose drain back into unit.
• Do not allow loops in the flexible steam hose
for more than 20 seconds.
• Allow enough time (approximately 2 minutes)
for steamer to preheat before use.
• Periodically lift steam nozzle/handle as high as
possible to let any condensation in flexible
steam hose drain back into unit.
• Normal during use. To maintain steam flow,
fully extend flexible steam hose to allow steam
to flow freely.
840193801 ENv05.qxd:840135000 Ev00.qxd 11/19/10 9:26 AM Page 9