EasyManua.ls Logo

RKI Instruments 65-2340RKSS - Overview; Specifications

RKI Instruments 65-2340RKSS
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65-2340RKSS Toxic Gas Transmitter 1
Overview
This manual describes the 65-2340RKSS toxic gas transmitter. This manual also describes
how to install, start up, maintain, and calibrate the toxic gas transmitter when used with a
gas monitoring controller. A parts list at the end of this manual lists replacement parts and
accessories for the toxic gas transmitter.
The 65-2340RKSS toxic gas transmitter can be used for various target gases which are
listed in Table 1 below. For a particular target gas, the part number of the toxic transmitter
will be of the format 65-2340RKSS-XXX. For example, 65-2340RKSS-NH3 is for ammonia
(NH
3
) detection.
Specifications
Table 1 lists specifications for the toxic gas transmitter.
WARNING: When using the 65-2340RKSS, you must follow the instructions and
warnings in this manual to assure proper and safe operation of the
65-2340RKSS and to minimize the risk of personal injury. Be sure to
maintain and periodically calibrate the 65-2340RKSS as described in this
manual.
Table 1: Specifications
Target Gas 65-2340RKSS-ASH3: Arsine (AsH
3
)
65-2340RKSS-CL2: Chlorine (Cl
2
)
65-2340RKSS-CL-10: Chlorine (Cl
2
)
65-2340RKSS-HCN: Hydrogen Cyanide (HCN)
65-2340RKSS-NH3: Ammonia (NH
3
)
65-2340RKSS-SO2: Sulphur Dioxide (SO
2
)
65-2340RKSS-PH3: Phosphine (PH
3
)
Sampling Method Diffusion
Detection Range AsH
3
: 0 - 1.50 ppm
Cl
2
: 0 - 3.00 ppm
Cl
2
: 0 - 10.0 ppm
HCN: 0 - 15.0 ppm
NH
3
: 0 - 75.0 ppm
SO
2
: 0 - 6.00 ppm
PH
3
: 0 - 1.00 ppm
Accuracy ± 10% of reading or ± 5% of full scale (whichever is greater)
Signal Output 4 to 20 mA
Response Time Cl
2
and NH
3
: T90 in 90 seconds
All others: T90 in 45 seconds
Operating Temperature &
Humidity
14°F to 104°F (-10°C to 40°C)
20% to 90% Relative Humidity

Related product manuals