ISSUE 2016 Rev 1 - Installation Manual
3
RM Cylinders
Intercyl
INSTALLATION MANUAL
Issue 2016 - Rev 1
Tested to BS EN 12897 : 2006
FOR MORE INFORMATION, GO TO:
WWW.RMCYLINDERS.COM
No
te: By installing this product you agree to be bound by our Conditions of Sale found within
this manual and available for download via our website.
Question and Answer IconNeed help?

Do you have a question about the RM Cylinders Intercyl and is the answer not in the manual?

RM Cylinders Intercyl Specifications

General IconGeneral
BrandRM Cylinders
ModelIntercyl
CategoryBoiler
LanguageEnglish

Summary

Product Specifications Overview

Component Checklist and Requirements

General Installation Requirements

Specifies that the cylinder must be installed, commissioned, and maintained by a competent installer with G3 qualification.

General Installation and Commissioning Guide

Inlet Control Set

Describes the inlet control set components and their required positioning relative to the TPRV.

Boiler, Solar, and Immersion Heater Connections

Immersion Heater

Covers immersion heater specifications, installation, electrical supply requirements, and operational warnings.

Discharge Pipework and Tundish Installation

Discharge Pipework Requirements

Details pipe sizing, fall, material, and termination for safety discharge according to Building Regulation G3.

System Commissioning and Maintenance

Commissioning - filling the system

Step-by-step guide for filling the system, purging air, and checking connections for water tightness.

Service and Maintenance

Emphasizes annual servicing by competent installers using approved parts.

Annual Servicing Requirements

Outlines annual checks for relief valves, immersion heaters, interface disc level, and inlet control set filter.

Fault Finding: Inlet Control Group

Fault Finding: Tundish Issues

Fault Finding: Temperature & Pressure Valve

Fault Finding: Thermostats and Immersion Heater

Dual Thermostat - Fault Finding

Flowchart to diagnose issues with the dual thermostat, checking control and limit stat functions.

Immersion Heater - Fault Finding

Flowchart to diagnose immersion heater faults, checking power, thermostat, and element continuity.

Fault Finding: Energy Cut Out Thermostat

Hot Water System Commissioning Checklist

User Guide, Guarantee, and Service

Guarantee

Details the 25-year guarantee for the stainless steel vessel and conditions for validity.

Typical Wiring Diagrams Overview

Typical Wiring - S Plan, 1 Zone

Illustrates the wiring configuration for an S Plan system with one heating zone.