CMOS Memory Size Mismatch
The BIOS has detected a difference between the amount of RAM in the
system and the amount stored in the Setup program. Press <F2> or <DEL>
to run Setup. The correct memory size is recorded automatically.
HDD Controller Failure
The BIOS is unable to communicate with the hard disk. Switch off the
system and then check the power and interface cables to the drive. If this
error message returns when you switch on again, you may have a hardware
problem and should contact RM.
C: Drive Error D: Drive Error
The BIOS is not receiving a response from either hard disk drive C or D.
Check the type of hard disk selected in Setup. Re-run the auto-detect
function in the Setup program.
50 4: Maintenance, Service & Troubleshooting
C: Drive Failure D: Drive Failure
The BIOS is unable to obtain any response from either hard disk drive C or
D. You may have a serious problem with your hard disk and should contact
RM.
CMOS Time & Date Not Set
The time and/or date are not set. Run the Setup and set the date and time.