iii) Not Used
Display Shows: “XXX ˚C“
Press the (Cancel) button to revert back to the main menu.
iv) For Calibration Reset mode
(Prog>Service>Accept>Calib.Reset>Accept)
Display Shows: “Calib. Reset“
This function recalibrates the boiling water unit to boiling point. Press the (Accept)
button to recalibrate the boiling point. Press (Accept) again at the “Are You Sure”
prompt. Press the (Cancel) button to revert back to the Main menu.
v) To Display the Software Version
(Prog>Service>Accept>Software Version>Accept)
vi) Temp Show On/Off
(Prog>Service>Accept>TempShow ON/OFF)
This function allows the temperature of the water within the boiling water unit to be
displayed permanently on the screen. Press the (Accept) button to confirm
selection and the display reverts to the main menu
vii) TB Treq
(Prog>Service>Accept>TB Treq)
This function shows the user the temperature to which the unit is calibrated. Under
the letters TB the boiling calibration temperature is displayed. The temperature
displayed beneath the letters “Treq” indicates the temperature at which the unit will
maintain the water.
viii) Temperature override
(Prog>Service>Accept>Temp Override>Accept)
This function allows the serviceman to perform a fast unit calibration.
Keypad Lock
This function provides extra security to prevent tampering with the unit settings.
Default setting is disabled.
(Prog>Keypad Lock>Accept)
The message “Keylock Enabled” will display on screen. Press Accept key.
“Keypad locked” message will display on screen every time a timer button is
pressed.
To deactivate this function press Progr and Up buttons simultaneously for a period
of 5 seconds.