EasyManua.ls Logo

robatherm AR3 - Service Menu; Error Codes

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page: 10
i) To Select Remaining Life mode
(Prog>Filter Life>Accept>Remaining Life)
Display Shows: “Remaining Life”
“XXXX litres“
Press the (Cancel) or (Accept) button to revert back to the main menu.
ii) To Select the Filter Reset mode
(Prog> Filter Life >Accept>filter reset>Accept)
Display Shows: “Filter Reset
Press the (Accept) button to confirm selection at which time you are prompted “Are
you sure?”. Press (Accept) once more reset the filter and to return to the Filter Life
Menu.
Display Shows: “Set Filter Life” “4000 Litres”.
Pressing (UP) button scrolls to the filter OFF selection (this turns the filter count off
if a filter is not installed with the boiling water unit). Press the (Accept) button to
confirm selection and the display reverts to the Filter menu
Filter count can be adjusted in the range of 1000 litres to 14000 litres in increments
of 1000 litres
F) Service Menu
Select Appropriate Service Mode
i. Error Codes
ii. Boiling Temp
iii. Chiller Temp (Not Used)
iv. Calib Reset
v. Software Version
vi. Temp Show ON/OFF
vii. TB Treq
viii. Temp override
ix. i) Error Codes
(Prog>Service>Accept>Error Codes)
This function allows easy identification of problems occurring with the unit by
service technicians (see details on page 10 Product error codes).
ii) For Boiling Unit Display Temp mode
(Prog>Service>Accept>Boiling Temp)
Display Shows: “XXX ˚C“
This function displays the current hot water temperature.
Press the (Cancel) button to revert back to the main menu.