DC
12V DC output available
Table 3: Status LEDs
Function in normal mode
Function in service mode
LED1
Normal mode
None
LED2
None
Service mode
LED3
Blinking: Low level configuration error
ON: High level configuration error
not used
LED4
No memory card/ Memory card error
Unknown error
LED5
Event log error
IP address error
LED6
License error
Memory card error
LED7
Not used
Not used
LED8
Blinking: Proper functioning in normal mode
Blinking: Proper functioning in service mode
ON: Bootloader error
Table 4: Technical Specification
Supply voltage
17-22VAC, nominal 18VAC
11.5V-15VDC, nominal 12VDC,
22-26VDC, nominal 24VDC
Backup battery
13.8V/7Ah, charging current 300mA
Current consumption
100 mA for 18VAC (no loads on AUX/TML outputs)
Inputs
Eight inputs, electrically biased to +12V via 5.6kΩ resistor
Relay outputs
Two relay outputs with single NO/NC contact 30V/1.5A rated
Transistor outputs
Six open collector transistor outputs, 15VDC/150mA rated. Max. total current
sink by all outputs up to 3ADC.
Power supply outputs
12VDC/1A (AUX)
12VDC/0.2A (TML)
RS485 ports
Two RS485 communication ports
Ethernet port
10BASE-T 10/100Mb communication port
Wire lengths
1200m for RS485
150m for Wiegand and RACS CLK/DTA
Environmental class
(acc. to EN 50131-1)
Class I, indoor general conditions, temperature: +5°C to +40°C, relative
humidity: 10 to 95% (no condensation)
Dimensions H x W x D
72 x 175 x 30 mm
Weight
approx. 200g