MC16 Installation Manual.doc 2018-11-22
Blinking: Low level configuration error
ON: High level configuration error
No memory card/ Memory card error
Blinking: Proper functioning in normal mode
Blinking: Proper functioning in service mode
ON: Bootloader error
Table 4: Technical Specification
17-22VAC, nominal 18VAC
11.5V-15VDC, nominal 12VDC,
22-26VDC, nominal 24VDC
13.8V/7Ah, charging current 300mA
100 mA for 18VAC (no loads on AUX/TML outputs)
Eight inputs, electrically biased to +12V via 5.6kΩ resistor
Two relay outputs with single NO/NC contact 30V/1.5A rated
Six open collector transistor outputs, 15VDC/150mA rated. Max. total current
sink by all outputs up to 3ADC.
12VDC/1A (AUX)
12VDC/0.2A (TML)
Two RS485 communication ports
10BASE-T 10/100Mb communication port
1200m for RS485
150m for Wiegand and RACS CLK/DTA
Environmental class
(acc. to EN 50131-1)
Class I, indoor general conditions, temperature: +5°C to +40°C, relative
humidity: 10 to 95% (no condensation)