Serial bus analysis
R&S
®
RTM3000
342User Manual 1335.9090.02 ─ 09
3 or DATA_SDI_SSM   = <P><SSM><    Data     ><SDI><Label>
>3 or SYSTEM_DEFAULT or empty = Default format as defined in scope.
Example: ARINC 429 PTT file
# ---------------------------------------------------------------------------- 
@FILE_VERSION = 1.0
@PROTOCOL_NAME = arinc429
# ---------------------------------------------------------------------------- 
# Labels for ARINC protocol
# Column order: Numeric address (Label), Symbolic label, Word format
# ---------------------------------------------------------------------------- 
# ----Definition----
@PROTOCOL_NAME = arinc429
101o, Distance to Go, 0
102o, Time to Go, DATA_SDI
103o, Engine Discrete, DATA_SSM
104o, Latitude, 3
105o, Ground Speed, 4
106o, Magnetic heading
# ---------------------------------------------------------------------------- 
ARINC 429 (option R&S RTM-K7)