EasyManua.ls Logo

Rohr MIG-200FI - User Manual

Rohr MIG-200FI
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INVERTER IGBT MIG/MAG WELDING MACHINE
MIG-200FI • MIG-250FI
OPERATION MANUAL
Read this manual carefully before use and keep it for future reference. Failure to do so
may result in injury, property damage and may void the warranty.
Products covered by this manual may vary in appearance, assembly, inclusions,
specications, description or packaging.
V 3.0
English Français Deutsch Italiano Español

Questions and Answers

  • M
    Martin GravesAug 11, 2025
    What to do if the Rohr MIG-200FI Welding System is producing untidy welds?
    • B
      Brian MartinAug 11, 2025
      If your Rohr Welding System is producing untidy welds, make sure the feed speed isn't too fast and the protruding wire isn't too long. Also, ensure that the amp output isn't too high.
  • S
    Samuel ParkerAug 17, 2025
    What to do if the HF arc-striking sound can be heard but there is no welding output from my Rohr MIG-200FI Welding System?
    • K
      Kevin HicksAug 17, 2025
      If you hear the HF arc-striking sound but there's no welding output from your Rohr Welding System, check the torch and ground cables to make sure they're correctly connected and undamaged, replacing any faulty cables with the help of a qualified professional. Verify that the grounding cable is making good contact with the welding object. Also, inspect the end of the tungsten electrode and grind it down to a taper if needed; contaminated electrodes should be ground down.
  • G
    Gabriella StaffordAug 22, 2025
    How to fix oxidisation occurring during weld with Rohr Welding System?
    • D
      dkelleyAug 23, 2025
      To address oxidisation during welding with your Rohr Welding System: * Check that your Argon cylinder is open and pressurised to a minimum of 0.5Mpa. * Ensure the flow meter is open and providing sufficient flow (a minimum of 5 litres per minute is recommended, adjusting flow according to the welding current). * Inspect the torch to ensure it’s not blocked. * Confirm that the gas supply is fully airtight.
  • J
    Joshua WarrenAug 28, 2025
    What to do if Rohr MIG-200FI has no power?
    • T
      Timothy HoAug 28, 2025
      If there is no power to your Rohr Welding System, make sure the electric cable is in good condition and connected correctly. Faulty cables must not be used; they should be replaced by a qualified professional.
  • C
    Christopher TuckerSep 4, 2025
    Why is it hard to strike or maintain an arc with my Rohr MIG-200FI Welding System?
    • T
      Tiffany GuerraSep 4, 2025
      If it's hard to strike or maintain an arc with your Rohr Welding System, ensure you're using a high-quality tungsten electrode. Grind the end of the tungsten electrode to a taper, as an unground electrode can make it difficult to strike an arc or cause an unstable arc.