1. Error Messages
BULK DUMP: MIDI Buffer Full
Problem: Excessive data has been transmitted at once by
the bulk dump function.
Solution: Make adjustments to the exclusive data so that It
is sent in several "packets" of smaller amounts.
BULK DUMP: Check
Sum Error
Problem: The checksum value of the bulk dump is
incorrect.
Solution: Correct the exclusive
data.
BULK DUMP:
Internal RAM Write Protect
Problem: The internal memory
writs-protect function is on
and data received
during execution of the bulk
dump function cannot
be w/ritten or stored.
Solution: Set the protect function to
OFF in the Write mode
(P.I
66),
then perform
the operation again.
BULK DUMP: DATA Card
Not Ready
Problem: A DATA card
has not been inserted and the data
received by the bulk dump
function cannot be
written or stored.
Solution; insert
a DATA card correctly and securely
into
the DATA card
slot.
BULK DUMP: Improper
DATA Card
Problem: A DATA card
not properly formatted for use with
the JV-80 has been inserted
and the data
received by
bulk dump cannot be written or
stored.
Solution:
After formatting the DATA card
from the Write
mode (P.
162),
perform the operation
again.
BULK DUMP: DATA
Card Write Protect
Problem:
The protect switch of the
DATA card is on and
data received during execution
of the bulk dump
function could not be written
or stored.
Solution: Set the
protect switch of the
DATA card
to
off
(P.
155),
then
perform the operation again.