2.PUYiNG A PERFORMANCE
INT TRANS
int.Max
Velocity Internal Max Velocity Range:
1 27
This determines
the maximum
value
of the
velocity
data which
is
transmitted
for the transmit zone
of each Part.
This function
compresses the original velocity data sensed at the
main keyboard and transmits the altered
(reduced)
velocity
data to the Patch.
PERFCfRM
liSyn Lead
i;
Int.Max Uelocit-d
1 B 1
I- 1 2? 1 1 2? ! 1 80 1 1
88 I 58 I 1 1 5 11 1
^i
11 27
Play velocity data
is compressed
Int. Max Velocity
setting
[Example]
Max velocity
Velocity curve
Velocity
sesitivity
:
Using
the combined values
above results in the
velocity response shown
at the right.
J
The display
selected
by
{t]{2
pages)
Int.Range Lower
Int.Range
Upper
Internal Zone Key Range
Lower Range: C2
C7
Internal
Zone Key Range Upper Range:
C2
C7
These two pages
determine the low and high key
limits for the internal zone of each Part.
From the note data
received from the
main keyboard, only note data
falling
within
the specified key range
is passed on to the Patch.
PERFORM
tSyn
Lead
:
181
IC2 1C2 102
li::3
I n t.
.
Ra
n9e L o
w
e- r
C.5 !E3 IF4
IC2
PERFORM
tSyn
Lead :
Int.Range UF=-F=-ei-
1 8
1
ill
C? I C7
I C? i B5 B C?
I
E4
I £5 i C7
H
Only play data in this
range
is passed on
to the Patch
Key range
lower'
I
Key range upper
67.