15
Jan. 2014 ME-80
Connection Diagram
fig.connection-e.eps
Entering the Test Mode
1. Refer to the connection diagram, connect the respective pieces of equipment.
2. Adjust the PEDAL FX control to FREEZE.
3. Turn down all controls other than the PEDAL FX control all the way counterclockwise (minimum).
* The Test Mode is not entered unless the control is turned all the way.
4. Hold down WRITE and CTL and press POWER for 1 second or longer.
5. When 80 appears on the 7-segment LED display, release your hand.
The version appears on the 7-segment LED display.
Quitting the Test Mode
Press POWER for 1 second or longer to switch off the power.
Skipping Test Items
To advance to the next test item, hold down EXIT and press WRITE. Returning to the previous test item is not possible.
Test Items
1. Version Check and Device Check (p. 16)
2. Current-consumption Check, Voltage Detection Check and SW/LED Check (p. 16)
3. VR Test (p. 17)
4. EXP VR Check (p. 21)
5. AUDIO Check (p. 21)
6. Battery Operation Check (p. 23)