EasyManua.ls Logo

Roland SDE-1000 - Examples of RAM Failure

Roland SDE-1000
27 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SDE-1000/3000
FEB.
5,1984
EXAMPLES
OF
RAM
FAILURE
—No
data
on
one
RAM
pin
of
Main
Controller-
SDE-1000
INPUT
-18dBm
1kHz
RAM1
defective
RAM17&
IC28
pin6
5V/div
TP-3
5V/div
0.2ms/div
SDE-3000
INPUT
-10dBm
1kHz
All
RAMs
intact
TP-1
TR45/TR50
emitter
RAM1
(IC11)
INPUT
-18dBm
1kHz
TP-3
5V/div
IC16
pin6
2V/div
0.2ms/div
TP-3
5V/div
TP-1
20V/div
5/is/div
INPUT
-10dBm
1kHz
TP-1
TR45/TR50
emitter
0.2ms/div
TP-1
TP-2
5Ms/div
UM1
(IC11)
RAM1
RAM2
(IC10)
RAM2
RAM3
(IC9)
RAM3
22

Other manuals for Roland SDE-1000

Related product manuals