19
RootsScrub E Series (230V/50Hz)
TROUBLESHOOTING
PROBLEM CAUSE REMEDY
Faulty power switch Contact Roots service
Fuse blown Rectify the cause & replace fuse
Brush motor does not work Reset circuit breaker
Faulty brush motor or loose cable Contact Roots service
Faulty suction turbine switch Replace switch
Suction turbine fuse blown Replace the fuse
Faulty suction turbine Contact Roots service
Carbon brushes worn Contact Roots service
Water level in tank low Refill fresh water
Flow setting level at stop Set flow level to On
Water line clogged Remove and blow with compressed air
Water valve clogged Remove and clean
Dirty water tank is full Empty dirty water tank
Suction hose is clogged Remove debris
Squeegee is clogged Remove debris
Squeegee lip is worn Rotate or replace lips
Faulty vacuum hose Contact Roots service
Flow diverter is clogged Clean flow divertor
Tank gasket faulty Contact Roots service
Drain hose leak Hook up drain hose and close
Suction turbine faulty Contact Roots service
Worn tyre Replace tyre
Heavy soap concentration Clean tyres
No power - nothing works
Brush motor does not work
Poor water recovery
Poor traction
Suction turbine does not
work
Insufficient water flow
TROUBLESHOOTING CHART