www.rosseuropa.com
Operating Instructions | Air Preparation Products
3
ASSEMBLY
CAUTION
Wrong installation and ow direction are potentially
hazardous.
Install lters, lter regulators, and lubricators in mainte-
nance units or as individual untis only in vertical position.
Adhere to the ow direction (→) marked on each module.
COUPLING
If individual units are xed together to form a single combi-
nation, double nipples must be used between the individual
units.
• Apply adhesive to one thread of the double nipple.
• Screw the double nipple by hand into one unit.
• Apply adhesive to the other thread of the double nipple.
• Screw on the other unit by hand and align the combined
unit.
INSTALL WALL BRACKET
• Fasten support brackets to the module with two screws.
• Max. tightening torque: 1.6 Nm